Pressure valve test method

[ad_1]

Pressure valve test method

The pressure valve test method shared with you today is mainly divided into the following five points to introduce:

(1) Pressure regulation range and pressure stability test. Adjust the adjustment handwheel of the valve under test, from fully open to fully closed, and then fully open, and see the pressure rise and fall as well as the pressure regulation range from the pressure gauge. The pointer of the pressure gauge should rise and fall smoothly, and the pressure regulating range should meet the specified pressure regulating range. When the pressure is higher, the pressure pulsation value should not exceed the specified value.

(2) Test of internal leakage. Adjust the adjustment handwheel of the valve to be fully closed, adjust the overflow safety valve to the higher pressure of the valve under test, and then adjust the adjustment handwheel of the valve under test to measure the internal leakage at the overflow port of the valve under test.

(3) Unloading pressure test. Connect the remote control port of the relief valve to the oil tank, make the tested valve pass the test flow, measure the pressure of the oil inlet and outlet of the relief valve, and the difference is the unloading pressure of the tested valve.

(4) Pressure loss test. Adjust the adjustment handwheel of the valve under test to be completely loosened, and make the valve under test pass the inspection flow. The pressure of the inlet and outlet of the relief valve is measured by the pressure gauge, and the difference is the pressure loss of the valve under test.

(5) Open and close characteristic test. Close the overflow safety valve, adjust the valve under test to a higher pressure, adjust the overflow safety valve to gradually reduce the pressure of the system, and measure the overflow flow of the valve under test when it drops to the closing pressure of the valve under test. Adjust the overflow safety valve, start from the valve under test does not overflow, and gradually increase the pressure of the system. When the opening pressure of the valve under test rises, measure the overflow amount of the valve under test.
The above is the pressure valve test method shared with you today, I hope it will be helpful to you, please forward it~

[ad_2]

Share:

Send Us A Message

More Posts

Added to wishlistRemoved from wishlist 0
Add to compare
Metal Seated Lift Plug Valve manufacturer
Added to wishlistRemoved from wishlist 0
Add to compare
steam trap manufacturer
Added to wishlistRemoved from wishlist 0
Add to compare
Cast Steel Gate Valve-API
Added to wishlistRemoved from wishlist 0
Add to compare
Forged Steel Gate Valve
Added to wishlistRemoved from wishlist 0
Add to compare
Resilient Seat Gate Valve-DIN
Added to wishlistRemoved from wishlist 0
Add to compare
Resilient Seat Gate Valve-BS
Added to wishlistRemoved from wishlist 0
Add to compare
Resilient Seat Gate Valve-AWWA
Added to wishlistRemoved from wishlist 0
Add to compare
Resilient Seat Gate Valve-SOCKET
Added to wishlistRemoved from wishlist 0
Add to compare
Metal Seat Cast Iron Gate Valve-DIN
Added to wishlistRemoved from wishlist 0
Add to compare
Metal Seat Cast Iron Gate Valve-MSS
Added to wishlistRemoved from wishlist 0
Add to compare
Metal Seat Cast Iron Gate Valve-JIS
Added to wishlistRemoved from wishlist 0
Add to compare
Cast Steel Check Valve-DIN

LUCKY6S is Chinese leading manufacturer and supplier of industrial valves. which has over ten years of experience in manufacturing high-quality industrial valves, focuses on delivering safety, efficiency, and cost-effectiveness to every industry that requires automation. We are committed to supplying premium industrial valves and equipment to distributors, importers, and project managers worldwide. 

Top Valve Manufacturer

Newsletter

© 2018 All rights lucky6s

lucky6s-Best Valve manufacturer
Logo
Enable registration in settings - general
Compare items
  • Total (0)
Compare
0
Shopping cart